ANTRIEBSTECHNIK
6
2
5
KEB COMBIVERT F4-F
Name: Basis
17.09.98
Functional Description
Analog In- and Outputs
Chapter
Section
Page
Date
©
KEB Antriebstechnik, 1998
All Rights reserved
6
12
13
14
15
16
17
CRF
COM REF1 REF1 REF2 REF2
+
–
+
–
12
13
14
15
16
17
CRF
COM REF1 REF1 REF2 REF2
+
–
+
–
3 k
Ω
3 k
Ω
*
)
2. Setpoint setting:
External differential voltage
with
internal reference potential
(COM), i.e. REF1- and REF2- are connected to 0V-potential.
Thus the differential voltage is always formed between REF+
and COM.
Internal resistance Ri = 24 k
Ω
Example:
Setpoint = (REF1+) – (REF1-)
Setpoint = (-7 V) – (0 V)
Setpoint = -7 V
source of
external
differential
voltage
source of
external
differential
voltage *
)
Fig. 6.2.3
Connection
with
internal reference potential
*
)
also refer to parameter
AN.13 in Chapter 6.4
3. Setpoint setting:
Internal +10 V reference voltage, i.e. the setpoint can be
adjusted from 0...+10 V by means of setpoint potentiometer.
Internal resistance Ri = 24 k
Ω
Fig. 6.2.4
Connection with +10 V reference voltage
*
)
also refer to parameter
AN.13 in Chapter6.4