9
ANTRIEBSTECHNIK
6
8
9
KEB COMBIVERT F4-F
Name: Basis
19.05.99
6
Section
Page
Date
©
KEB Antriebstechnik, 1999
All Rights reserved
Chapter
Functional Description
Special Functions
The AUX-function offers the possibility to affect the setpoint value, speed controller
or torque limitation by way of the analog input REF2. In a special mode a torque
control can be realized. Parameter An.13 defines the function of the AUX-function.
An.13
AUX-Function
0
no function
1
The AUX-signal is added to the actual setpoint signal (analog or digital).
Setpoint = setpoint AUX-signal (-10 V ... +10 V)
2
The AUX-signal acts a multiplier for parameter CS.0 (KP-speed)
AUX 0...10 V ^
= gain 0...1
3
The AUX-signal acts as multiplier for parameter CS.1 (KI-speed)
AUX 0...10 V ^
= gain 0...1
4
The AUX-signal acts as multiplier for CS.0 and CS.1 (total gain); AUX
0...10 V ^
= gain 0...1
5
The AUX-signal acts as multiplier for parameter CS.6 and CS.7 (torque
limitation); AUX 0...10 V ^
= gain 0...1
6
Torque control (see Chapter 6.5.18 „Torque Control“)
6.8.3
AUX-Function
(An.13)