6
1
Name: Basis
KEB COMBIVERT F4-F
16
16.03.99
Fucntional Description
©
KEB Antriebstechnik, 1999
All Rights reserved
Chapter
Section
Page
Date
Adr.
min
max
default
2C04h
1
-
-
FFFF
0
Adr.
min
max
default
Adr.
min
max
default
2C01h
0,1
A
LTK
?
0
2C00h
1
hex
-
-
-
In-Parameter
The software version-number of the Host-CPU and the control hardware is encoded in this parameter.
1. digit:
C = F4-F
2. and 3. digit:
Software version ( e.g. 14 = 1.4 )
4. digit:
Special version ( 0 = Standard)
In. 4
Software version
6.1.5 Description of In-Parameter
In. 0
Inverter type
In. 1
Rated inverter current
Display of rated inverter current in A. The value is determined from the power circuit identification (LTK) and cannot be
changed.
The inverter type is represented as hexadecimal number. The bits have following significance:
hex
1
E
D
D
Display
binary
0 0 0 1 1 1 1 0 1 1 0 1 1 1 0 1
bit 0:
Voltage class
0 = 230V
1 = 400V
bit 1-5:
Unit size
z.B. 01110 = 14
bit 6-8:
Control type
000 = 0A.S4
011 = 0C.F4
bit 10:
free (default=1)
bit 11-12:
Maximal operating frequency
01 = 8kHz
11 = 16kHz
bit 9, 13-15: Housing size
0000 = G
0110 = L
0001 = D
1000 = M
0010 = H
1010 = N
0011 = E
1100 = R
0100 = K
1110 = free