Goodrive300
inverters Appendix A
269
Bit
Name
Function selection
receiving
PZD3
receiving
0
PZD4
receiving
0
PZD5
receiving
0
PZD6
receiving
0
PZD7
receiving
0
PZD8
receiving
0
PZD9
receiving
0
PZD10
receiving
0
PZD11
receiving
0
PZD12
receiving
1:Set frequency(0~Fmax(unit:0.01Hz))
2:Given PID, range(0~1000,1000 corresponds to
100.0%)
3:PID feedback, range(0~1000,1000 corresponds to
100.0%)
4:Torque set value(-3000~3000,1000 corresponds to
100.0% the rated current of the motor)
5:Set value of the forward rotation upper-limit
frequency(0~Fmax unit:0.01Hz))
6:Set value of the reversed rotation upper-limit
frequency(0~Fmax(unit:0.01Hz))
7:Electromotion torque upper limit (0~3000,1000
corresponds to 100.0%of the rated current of the motor)
8:Braking torque upper limit (0~2000,1000 corresponds
to 100.0% of the rated current of the motor)
9:Virtual input terminals command
Range:0x000~0x1FF
10:Virtual output terminals command
Range:0x00~0x0F
11:Voltage setting value(special for V/F separation)
(0~1000,1000 corresponds to 100.0% the rated voltage
of the motor)
12:AO output set value 1
(-1000~1000,1000 corresponds to 100.0%)
13:AO output set value 2
(-1000~1000,1000 corresponds to 100.0%)
0
State word (SW):
The first word of PZD response message is state word (SW) of inverter, the definition of state
word is as follows:
State Word (SW) of Goodrive300 (SW)
Bit
Name
Value
State/Description
1
Forward running
0~7
RUN STATE BYTE
2
Reverse running
Summary of Contents for GD300-004G-4
Page 1: ...3...
Page 148: ...Goodrive300 inverters Basic operation instruction 147...
Page 159: ...Goodrive300 inverters Basic operation instruction 158...
Page 164: ...Goodrive300 inverters Basic operation instruction 163...
Page 173: ...Goodrive300 inverters Basic operation instruction 172...
Page 189: ...Goodrive300 inverters Basic operation instruction 188...
Page 204: ...Goodrive300 inverters Basic operation instruction 203...
Page 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Page 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Page 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...