![INVT GD300-004G-4 Operation Manual Download Page 280](http://html1.mh-extra.com/html/invt/gd300-004g-4/gd300-004g-4_operation-manual_2085739280.webp)
Goodrive300
inverters Appendix B
279
electrical,electronic and programmable electronic control
systems
IEC/EN 61800-3:2004
Adjustable speed electrical power drive systems. Part 3: EMC
requirements and specific test methods
IEC/EN 61800-5-1:2007
Adjustable speed electrical power drive systems – Part 5-1:
Safety requirements – Electrical, thermal and energy
IEC/EN 61800-5-2:2007
Adjustable speed electrical power drive systems – Part 5-2:
Safety requirements. Functional.
B.5.1 CE marking
The CE mark is attached to the drive to verify that the drive follows the provisions of the
European Low Voltage and EMC Directives.
B.5.2 Compliance with the European EMC Directive
The EMC Directive defines the requirements for immunity and emissions of electrical
equipment used within the European Union. The EMC product standard (EN 61800-3:2004)
covers requirements stated for drives. See section
EMC regulations
B.6 EMC regulations
EMC product standard (EN 61800-3:2004) contains the EMC requirements to the inverter.
First environment: domestic environment (includes establishments connected to a
low-voltage network which supplies buildings used for domestic purposes).
Second environment includes establishments connected to a network not directly supplying
domestic premises.
Four categories of the inverter:
Inverter of category C1: inverter of rated voltage less than 1000 V and used in the first
environment.
Inverter of category C2: inverter of rated voltage less than 1000 V other than pins, sockets
and motion devices and intended to be installed and commissioned only by a professional
electrican when used in the first environment.
Note:
IEC/EN 61800-3 in EMC standard doesn’t limit the power distribution of the inverter,
but it defines the ustage, installation and commission. The professional electrician has
necessary skills in installing and/or commissioning power drive systems, including their EMC
aspects.
Inverter of category C3: inverter of rated voltage less than 1000 V and used in the second
environment other than the first one
Summary of Contents for GD300-004G-4
Page 1: ...3...
Page 148: ...Goodrive300 inverters Basic operation instruction 147...
Page 159: ...Goodrive300 inverters Basic operation instruction 158...
Page 164: ...Goodrive300 inverters Basic operation instruction 163...
Page 173: ...Goodrive300 inverters Basic operation instruction 172...
Page 189: ...Goodrive300 inverters Basic operation instruction 188...
Page 204: ...Goodrive300 inverters Basic operation instruction 203...
Page 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Page 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Page 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...