![INVT GD300-004G-4 Operation Manual Download Page 293](http://html1.mh-extra.com/html/invt/gd300-004g-4/gd300-004g-4_operation-manual_2085739293.webp)
Goodrive300
inverters Appendix D
292
Check that the voltage degree of the inverter complies with the voltage of the
supply power voltage.
D.4 Cables
D.4.1 Power cables
Dimension the input power and motor cables according to local regulations.
•
The input power and the motor cables must be able to carry the corresponding load
currents.
•
The cable must be rated for at least 70 °C maximum permissible temperature of the
conductor in continuous use.
•
The conductivity of the PE conductor must be equal to that of the phase conductor
(same cross-sectional area).
•
Refer to chapter
Technical Data
for the EMC requirements.
A symmetrical shielded motor cable (see the figure below) must be used to meet the EMC
requirements of the CE.
A four-conductor system is allowed for input cabling, but a shielded symmetrical cable is
recommended. Compared to a four-conductor system, the use of a symmetrical shielded
cable reduces electromagnetic emission of the whole drive system as well as motor bearing
currents and wear.
Note: A separate PE conductor is required if the conductivity of the cable shield is not
sufficient for the purpose.
To function as a protective conductor, the shield must have the same cross-sectional area as
the phase conductors when they are made of the same metal.
To effectively suppress radiated and conducted radio-frequency emissions, the shield
conductivity must be at least 1/10 of the phase conductor conductivity. The requirements are
easily met with a copper or aluminum shield. The minimum requirement of the motor cable
shield of the drive is shown below. It consists of a concentric layer of copper wires. The
better and tighter the shield, the lower the emission level and bearing currents.
Summary of Contents for GD300-004G-4
Page 1: ...3...
Page 148: ...Goodrive300 inverters Basic operation instruction 147...
Page 159: ...Goodrive300 inverters Basic operation instruction 158...
Page 164: ...Goodrive300 inverters Basic operation instruction 163...
Page 173: ...Goodrive300 inverters Basic operation instruction 172...
Page 189: ...Goodrive300 inverters Basic operation instruction 188...
Page 204: ...Goodrive300 inverters Basic operation instruction 203...
Page 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Page 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Page 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...