D.5.1 The inverters of AC 3PH 380V(-15%)~440V(+10%)
Model
Breaker (A)
Breaker (A)
The rated working
current of the
contactor(A)
GD300-1R5G-4
15
16
10
GD300-2R2G-4
17.4
16
10
GD300-004G-4
30
25
16
GD300-5R5G-4
45
25
16
GD300-7R5G-4
60
40
25
GD300-011G-4
78
63
32
GD300-015G-4
105
63
50
GD300-018G-4
114
100
63
GD300-022G-4
138
100
80
GD300-030G-4
186
125
95
GD300-037G-4
228
160
120
GD300-045G-4
270
200
135
GD300-055G-4
315
200
170
GD300-075G-4
420
250
230
GD300-090G-4
480
315
280
GD300-110G-4
630
400
315
GD300-132G-4
720
400
380
GD300-160G-4
870
630
450
GD300-200G-4
1110
630
580
GD300-220G-4
1230
800
630
GD300-250G-4
1380
800
700
GD300-280G-4
1500
1000
780
GD300-315G-4
1740
1200
900
GD300-350G-4
1860
1280
960
GD300-400G-4
2010
1380
1035
Summary of Contents for GD300-004G-4
Page 1: ...3...
Page 148: ...Goodrive300 inverters Basic operation instruction 147...
Page 159: ...Goodrive300 inverters Basic operation instruction 158...
Page 164: ...Goodrive300 inverters Basic operation instruction 163...
Page 173: ...Goodrive300 inverters Basic operation instruction 172...
Page 189: ...Goodrive300 inverters Basic operation instruction 188...
Page 204: ...Goodrive300 inverters Basic operation instruction 203...
Page 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Page 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Page 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...