Goodrive300
inverters Function codes
86
Functi
on
code
Name
Detailed instruction of parameters
Default
value
Modif
y
P05.35
Correspond
ing setting
of
the upper
limit of AI1
100.0%
○
P05.36
AI1 input
filter time
0.100s
○
P05.37
Lower limit
of AI2
0.00V
○
P05.38
Correspond
ing setting
of the lower
limit of AI2
0.0%
○
P05.39
Upper limit
of AI2
10.00V
○
P05.40
Correspond
ing setting
of
the upper
limit of AI2
100.0%
○
P05.41
AI2 input
filter time
0.100s
○
P05.42
Lower limit
of
AI3
-10.00V
○
P05.43
Correspond
ing setting
of the lower
limit of AI3
-100.0
%
○
P05.44
Middle
100.0% is different. See the application for detailed
information.
The figure below illustrates different applications:
Input filter time: this parameter is used to adjust the
sensitivity of the analog input. Increasing the value
properly can enhance the anti-interference of the
analog, but weaken the sensitivity of the analog
input.
Note: Analog AI1 and AI2 can support 0~10V or
0~20mA input, when AI1 and AI2 selects 0~20mA
input, the corresponding voltage of 20mA is 5V. AI3
can support the output of -10V~+10V.
The setting range of P05.32:0.00V~P05.34
The setting range of P05.33:-100.0%~100.0%
The setting range of P05.34:P05.32~10.00V
The setting range of P05.35:-100.0%~100.0%
The setting range of P05.36:0.000s~10.000s
The setting range of P05.37:0.00V~P05.39
The setting range of P05.38:-100.0%~100.0%
The setting range of P05.39:P05.37~10.00V
The setting range of P05.40:-100.0%~100.0%
The setting range of P05.41:0.000s~10.000s
The setting range of P05.42:-10.00V~P05.44
0.00V
○
Summary of Contents for GD300-004G-4
Page 1: ...3...
Page 148: ...Goodrive300 inverters Basic operation instruction 147...
Page 159: ...Goodrive300 inverters Basic operation instruction 158...
Page 164: ...Goodrive300 inverters Basic operation instruction 163...
Page 173: ...Goodrive300 inverters Basic operation instruction 172...
Page 189: ...Goodrive300 inverters Basic operation instruction 188...
Page 204: ...Goodrive300 inverters Basic operation instruction 203...
Page 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Page 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Page 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...