![INVT GD300-004G-4 Operation Manual Download Page 234](http://html1.mh-extra.com/html/invt/gd300-004g-4/gd300-004g-4_operation-manual_2085739234.webp)
Goodrive300
inverters Maintenance and hardware diagnostics
233
Checking
Item
Method
Criterion
ending to coagulate
or measure with
multimeters
standard value.
Transform
ers
and
reactors
Ensure there is no abnormal
vibration, noise and smelling,
Hearing, smelling
and visual
examination
NA
Ensure whether there is
vibration noise in the
workrooms.
Hearing
NA
Electroma
gnetism
contactors
and
relays
Ensure the contactor is good
enough.
Visual examination
NA
Ensure there are no loose
screws and contactors.
Fasten up
NA
Ensure there is no smelling
and color-changing.
Smelling and visual
examination
NA
Ensure there are no
crackles, damage distortion
and rust.
Visual examination
NA
Control
circuit
PCB
and
plugs
Ensure there is no weeping
and distortion to the
capacitors.
Visual examination
or estimate the
usage time
according to the
maintenance
information
NA
Estimate whether there is
abnormal noise and
vibration.
Hearing and Visual
examination or
rotate with hand
Stable rotation
Cooling
system
Cooling
fan
Estimate there is no losses
screw.
Tighten up
NA
Summary of Contents for GD300-004G-4
Page 1: ...3...
Page 148: ...Goodrive300 inverters Basic operation instruction 147...
Page 159: ...Goodrive300 inverters Basic operation instruction 158...
Page 164: ...Goodrive300 inverters Basic operation instruction 163...
Page 173: ...Goodrive300 inverters Basic operation instruction 172...
Page 189: ...Goodrive300 inverters Basic operation instruction 188...
Page 204: ...Goodrive300 inverters Basic operation instruction 203...
Page 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Page 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Page 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...