Goodrive300
inverters Function codes
106
Functi
on
code
Name
Detailed instruction of parameters
Default
value
Modif
y
The setting range of P08.17: 0.1~3600.0s
The setting range of P08.18: 0.1~3600.0s
P08.19
Setting
length
0m
○
P08.20
Actual
length
0m
●
P08.21
Pulse per
rotation
1
○
P08.22
Alxe
perimeter
10.00c
m
○
P08.23 Length ratio
1.000
○
P08.24
Length
correcting
coefficient
The function codes of setting length, actual length
and unit pulse are mainly used to control the fixed
length.
The length is counted by the pulse signal of HDI
terminals input and the HDI terminals are needed
to set as the length counting input.
Actual length
=
the length counting input pulse
/
unit
pulse
When the actual length P08.20 exceeds the setting
length P08.19, the multi-function digital output
terminals will output ON.
Setting range of P08.19: 0~65535m
Setting range of P08.20:0~65535m
Setting range of P08.21:1~10000
Setting range of P08.22:0.01~100.00cm
Setting range of P08.23:0.001~10.000
Setting range of P08.24:0.001~1.000
1.000
○
P08.25
Setting
counting
value
0
○
P08.26
Reference
counting
value
The counter works by the input pulse signals of the
HDI terminals.
When the counter achieves a fixed number, the
multi-function output terminals will output the signal
of “fixed counting number arrival” and the counter
go on working; when the counter achieves a setting
number, the multi-function output terminals will
output the signal of “setting counting number
arrival”, the counter will clear all numbers and stop
to recount before the next pulse.
The setting counting value P08.26 should be no
more than the setting counting value P08.25.
0
○
Summary of Contents for GD300-004G-4
Page 1: ...3...
Page 148: ...Goodrive300 inverters Basic operation instruction 147...
Page 159: ...Goodrive300 inverters Basic operation instruction 158...
Page 164: ...Goodrive300 inverters Basic operation instruction 163...
Page 173: ...Goodrive300 inverters Basic operation instruction 172...
Page 189: ...Goodrive300 inverters Basic operation instruction 188...
Page 204: ...Goodrive300 inverters Basic operation instruction 203...
Page 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Page 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Page 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...