Goodrive300
inverters Basic operation instruction
199
Function
code
Name
Detailed instruction of parameters
Default
value
6:Frequency degree test FDT1
7:Frequency degree test FDT2
8:Frequency arrival
9:Zero speed running
10:Upper limit frequency arrival
11:Lower limit frequency arrival
12:Ready for operation
13:Pre-magnetizing
14:Overload pre-alarm
15: Underload pre-alarm
16:Completion of simple PLC stage
17:Completion of simple PLC cycle
18:Setting count value arrival
19:Defined count value arrival
20:External fault valid
21:Length arrival
22:Running time arrival
23:MODBUS communication virtual
terminals output
24:PROFIBUS communication virtual
terminals output
25: Ethernet communication virtual
terminals output
26~30: Reserved
P06.05
Polarity of output
terminals
0x00~0x0F
0x00
P06.06
Y switch-on delay time 0.000~50.000s
0.000s
P06.07
Y switch-off delay time
0.000~50.000s
0.000s
P06.08
HDO switch-on delay time
0.000~50.000s
(valid only when P06.00=1)
0.000s
P06.09
HDO switch-off delay time
0.000~50.000s
(valid only when P06.00=1)
0.000s
P06.10
RO1 switch-on delay time 0.000~50.000s
0.000s
Summary of Contents for GD300-004G-4
Page 1: ...3...
Page 148: ...Goodrive300 inverters Basic operation instruction 147...
Page 159: ...Goodrive300 inverters Basic operation instruction 158...
Page 164: ...Goodrive300 inverters Basic operation instruction 163...
Page 173: ...Goodrive300 inverters Basic operation instruction 172...
Page 189: ...Goodrive300 inverters Basic operation instruction 188...
Page 204: ...Goodrive300 inverters Basic operation instruction 203...
Page 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Page 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Page 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...