Goodrive300
inverters Basic operation instruction
198
Set value
Function
Instructions
detailed instruction.
16
Simple PLC stage completion Output signal if the simple PLC stage is completed.
17
Simple PLC cycle completion
Output signal if the 1 simple PLC cycle is
completed.
18
Set counting arrival
Output ON signal if the detected counting exceeds
the set value of P08.25.
19
Fixed counting arrival
Output ON signal if the detected counting exceeds
the set value of P08.26.
20
External fault valid
Output ON signal if external fault occurs.
21
Length arrival
Output ON signal if the actual detected length
exceeds the se length by P08.19.
22
Running time arrival
Output ON signal if the accumulative running time
of the inverter exceeds the setting time by P08.27.
23
MODBUS communication
virtual terminal output
Output corresponding signal according to the
setting value of MODBUS. Output ON signal if the
setting value is 1 and output OFF signal if the
setting value is 0.
24
POROFIBUS communication
virtual terminal output
Output corresponding signal according to the
setting value of PROFIBUS. Output ON signal if the
setting value is 1 and output OFF signal if the
setting value is 0.
25~30
Reserved
Relative parameters list:
Function
code
Name
Detailed instruction of parameters
Default
value
P06.00
HDO output
0:Open collector pole high speed pulse
output
1: Open collector pole output
0
P06.01
Y output
0
P06.02
HDO output
0
P06.03
Relay RO1 output
1
P06.04
Relay RO2 output
0:Invalid
1:In operation
2:Forward rotation operation
3:Reverse rotation operation
4: Jogging operation
5:The inverter fault
5
Summary of Contents for GD300-004G-4
Page 1: ...3...
Page 148: ...Goodrive300 inverters Basic operation instruction 147...
Page 159: ...Goodrive300 inverters Basic operation instruction 158...
Page 164: ...Goodrive300 inverters Basic operation instruction 163...
Page 173: ...Goodrive300 inverters Basic operation instruction 172...
Page 189: ...Goodrive300 inverters Basic operation instruction 188...
Page 204: ...Goodrive300 inverters Basic operation instruction 203...
Page 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Page 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Page 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...