Goodrive300
inverters Basic operation instruction
170
Function
code
Name
Detailed instruction of parameters
Default
value
3: Ethernet communication shifting
4: Reserved
LED tens: shifting enabling in operation
0: Disabled
1: Enabled
0x00~0x14
P12.00
Motor type 2
0:Asynchronous motor
1:Synchronous motor
0
P12.01
Rated power of
asynchronous motor 2
0.1~3000.0kW
Depend
on model
P12.02
Rated frequency of
asynchronous motor 2
0.01Hz~P00.03(the Max. frequency)
50.00Hz
P12.03
Rated speed of
asynchronous motor 2
1~36000rpm
Depend
on model
P12.04
Rated voltage of
asynchronous motor 2
0~1200V
Depend
on model
P12.05
Rated current of
asynchronous motor 2
0.8~6000.0A
Depend
on model
P12.06
Stator resistor of
asynchronous motor 2
0.001~65.535Ω
Depend
on model
P12.07
Rotor resistor of
asynchronous motor 2
0.001~65.535Ω
Depend
on model
P12.08
Leakage inductance of
asynchronous motor 2
0.1~655.35mH
Depend
on model
P12.09
Mutual inductance of
asynchronous motor 2
0.1~655.35mH
Depend
on model
P12.10
Non-load current of
asynchronous motor 2
0.1~6553.5A
Depend
on model
P12.15
Rated power of
synchronous motor 2
0.1~3000.0kW
Depend
on model
P12.16
Rated frequency of
synchronous motor 2
0.01Hz~P00.03(the Max. frequency)
50.00Hz
P12.17
Number of poles pairs for
synchronous motor 2
1~50
2
Summary of Contents for GD300-004G-4
Page 1: ...3...
Page 148: ...Goodrive300 inverters Basic operation instruction 147...
Page 159: ...Goodrive300 inverters Basic operation instruction 158...
Page 164: ...Goodrive300 inverters Basic operation instruction 163...
Page 173: ...Goodrive300 inverters Basic operation instruction 172...
Page 189: ...Goodrive300 inverters Basic operation instruction 188...
Page 204: ...Goodrive300 inverters Basic operation instruction 203...
Page 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Page 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Page 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...