Functi
on
code
Name
Detailed instruction of parameters
Default
value
Modif
y
P05.08
S8
terminals
function
selection
0
◎
P05.09
HDI
terminal
function
selection
28:Counter reset
29:Torque control disabling
30:ACC/DEC disabling
31:Counter trigging
32:Length reset
33:Cancel the frequency change setting
temporarily
34:DC brake
35:Shift the motor 1 into motor 2
36:Shift the command to the keypad
37:Shift the command to the terminals
38:Shift the command to the communication
39:Pre-magnetized command
40:Comsumption power clear
41: Comsumption power holding
42~63:Reserved
0
◎
P05.10
Polarity
selection of
the input
terminals
The function code is used to set the polarity of the
input terminals.
Set the bit to 0, the input terminal is anode.
Set the bit to 1, the input terminal is cathode.
BIT0
BIT2
BIT3
BIT4
BIT5
S1
S2
S3
S4
S5
BIT6
BIT7
BIT8
BIT9
S6
S7
S8
HDI
The setting range:0x000~0x1FF
0x000
○
P05.11
ON-OFF
filter time
Set the sample filter time of S1~S8 and HDI
terminals. If the interference is strong, increase the
parameter to avoid the disoperation.
0.000~1.000s
0.010s
○
P05.12
Virtual
terminals
setting
Enable the input function of virtual terminals at the
communication mode.
0:Virtual terminals is invalid
1:MODBUS communication virtual terminals are
0
◎
Summary of Contents for GD300-004G-4
Page 1: ...3...
Page 148: ...Goodrive300 inverters Basic operation instruction 147...
Page 159: ...Goodrive300 inverters Basic operation instruction 158...
Page 164: ...Goodrive300 inverters Basic operation instruction 163...
Page 173: ...Goodrive300 inverters Basic operation instruction 172...
Page 189: ...Goodrive300 inverters Basic operation instruction 188...
Page 204: ...Goodrive300 inverters Basic operation instruction 203...
Page 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Page 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Page 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...