Power Range
Redundancy
Mode
PSU Qty.
Recommended Slots
2500 W < P < 5000 W
2+1
redundancy
3
PSU1, PSU2, PSU4
5000 W < P < 7500 W
3+1
redundancy
4
PSU1, PSU2, PSU4, PSU5
7500 W < P < 10000 W
4+1
redundancy
5
PSU1, PSU2, PSU3,
PSU4, PSU5
10000 W < P < 12500 W
5+1
redundancy
6
PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
2500 W < P < 5000 W
2+2
redundancy
4
PSU1, PSU2, PSU4, PSU5
5000 W < P < 7500 W
3+3
redundancy
6
PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
Table 2-14
Configuration policies for the 3000 W HVDC PSU (260 V DC to 400 V DC input
voltage; 3000 W output power)
Power Range
Redundancy
Mode
PSU Qty.
Recommended Slots
P < 3000 W
Non-
redundancy
1
PSU1
3000 W < P < 6000 W
Non-
redundancy
2
PSU1, PSU4
6000 W < P < 9000 W
Non-
redundancy
3
PSU1, PSU2, PSU4
9000 W < P < 12000 W
Non-
redundancy
4
PSU1, PSU2, PSU4,
PSU5
12000 W < P < 15000 W
Non-
redundancy
2
PSU1, PSU2, PSU3,
PSU4, PSU5
P < 3000 W
1+1
redundancy
2
PSU1, PSU4
3000 W < P < 6000 W
2+1
redundancy
3
PSU1, PSU2, PSU4
6000 W < P < 9000 W
3+1
redundancy
4
PSU1, PSU2, PSU4,
PSU5
9000 W < P < 12000 W
4+1
redundancy
5
PSU1, PSU2, PSU3,
PSU4, PSU5
E9000 Server
User Guide
2 Overview
Issue 25 (2019-11-30)
Copyright © Huawei Technologies Co., Ltd.
28