Step 2
Select the license operation based on the type of the switch module to be replaced and the
spare part type of the switch module.
Table 6-2
License operations
Type of the Switch
Module to Be Replaced
Spare Part Type of the
Switch Module
License Operation
24 ports
24 ports
License operations are not
required.
20+4 ports
1. Apply for a POD license.
For details, see the
application form and
"Applying for a License" in
the
CXxxx Switch Module
User Guide
.
2. Import the POD license.
For details, see
Importing and
Transferring Licenses
(Only for the CX210 and
CX912)
.
20+4 ports (The POD license
has been activated.)
20 ports
You do not need to apply
for the POD license, but you
need to transfer the POD
license. For details, see
6.3.8 Importing and
Transferring Licenses
(Only for the CX210 and
CX912)
.
20 ports
20 ports
License operations are not
required.
----End
6.3.3 Backing Up the Configuration Files
Procedure
Step 1
Log in to the switch module and the MM910 CLI.
The default user name and password of the switch module are
root
and
Huawei12#$
, respectively.
Step 2
Obtain the
CXxxx Switch Module User Guide
at
Support > Intelligent Servers > Blade
Step 3
Determine the switch module to be replaced.
shows the switch module slot numbers.
E9000 Server
User Guide
6 Parts Replacement
Issue 25 (2019-11-30)
Copyright © Huawei Technologies Co., Ltd.
114