license and then import it. For details, see
6.3.2 Applying for a License (Only for
6.3.8 Importing and Transferring Licenses (Only
–
If the preceding licenses do not exist, you do not need to perform any operation on
the license.
l
You may need to upgrade software during the replacement. Therefore, obtain the latest
software of the switch module to be replaced at the
Huawei technical support website
before the replacement.
l
If the switch module to be replaced is CX710:
a.
Run the following command on the CLI of the 40GE converged switching plane to
check the current version of the 40GE converged switching plane:
<HUAWEI>
display version
Figure 6-12
Displayed information (example)
b.
Confirm the PCB version of the CX710.
n
If
PCB Version
is
VER A
, continue to replace the switch module.
n
If
PCB Version
is
VER B
, the CPLD software cannot be rolled back to
version 0.08 or 0.09.
Table 6-1
Preparations
Item
Name
Description
Software
TFTP server software
An example is
tftpd32.exe
,
which is used to remotely
connect to a switch module.
E9000 Server
User Guide
6 Parts Replacement
Issue 25 (2019-11-30)
Copyright © Huawei Technologies Co., Ltd.
111