Figure 6-22
Output information of the SOL serial port
2.
Use the
display version
command to check the current software version.
–
Information similar to the following is displayed for the V5 platform:
<Fabric>
display version
BoardName : CX910
CPLD Version : 007
PCB Version : VER.C
rcw Version : 001
backup rcw Version : 001
Bootrom Version : 018
Creation Time : May 2 2013, 10:34:37
Backup Bootrom Version : 018
Creation Time : May 2 2013, 10:34:37
Switch Version : 1.1.3.300.2
Creation Time : May 17 2013, 16:32:48
Backup Switch Version : 1.1.3.300.2
FC BoardName : M8PA
FC PCB Version : VER.A
FC Firmware Version : V1P10-FC
The software version is V5 if the command output contains
Switch Version
.
–
Information similar to the following is displayed for the V8 platform:
<HUAWEI>
display version
Huawei Versatile Routing Platform Software
VRP (R) software, Version 8.80 (OSCA V100R002C01)
Copyright (C) 2012-2014 Huawei Technologies Co., Ltd.
HUAWEI OSCA uptime is 11 days, 22 hours, 15 minutes
CX910_10GE(Master) 4 : uptime is 11 days, 22 hours, 15 minutes
StartupTime 2014/10/25 12:31:35
Memory Size : 2048 M bytes
Flash Size : 1024 M bytes
CX910_10GE version information
1. PCB Version : CX910_10GE VER C
2. MAB Version : 1
3. Board Type : CX910_10GE
4. CPLD1 Version : 101
5. BIOS Version : 2.43
6. Software Version : 2.14
The software version is V8 if the command output contains
Software Version
.
3.
Select an operation based on the current software version.
–
If the new switch module uses V5 software and the old switch module uses V8
software, upgrade the software of the new switch module to the latest V8 version.
For details about how to upgrade the software from V5 to V8, contact Huawei
technical support.
–
If the new switch module uses V8 software and the old switch module uses V5
software, see
4.
Use the
display vlan
command to view the saved configuration. The VLAN list is
.
–
If the current switch module is CX311 and the command output contains only
VLAN 1 and VLAN 1002, upgrade the switch module software to the latest version
by referring to the
E9000 Server V100R001 Upgrade Guide
up Ethernet configuration file by referring to "Restoring the Configuration File" in
the
CXxxx Switch Module User Guide
.
E9000 Server
User Guide
6 Parts Replacement
Issue 25 (2019-11-30)
Copyright © Huawei Technologies Co., Ltd.
121