Power Range
Redundancy
Mode
PSU Qty.
Recommended Slots
4000 W < P < 4800 W
Non-
redundancy
6
PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
P < 800 W
1+1
redundancy
2
PSU1, PSU4
800 W < P < 1600 W
2+1
redundancy
3
PSU1, PSU2, PSU4
1600 W < P < 2400 W
3+1
redundancy
4
PSU1, PSU2, PSU4, PSU5
2400 W < P < 3200 W
4+1
redundancy
5
PSU1, PSU2, PSU3,
PSU4, PSU5
3200 W < P < 4000 W
5+1
redundancy
6
PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
800 W < P < 1600 W
2+2
redundancy
4
PSU1, PSU2, PSU4, PSU5
1600 W < P < 2400 W
3+3
redundancy
6
PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
DC PSUs
Table 2-13
Configuration policies for the 2500 W DC PSU (
–
48 V DC to
–
60 V DC input
voltage; 2500 W output power)
Power Range
Redundancy
Mode
PSU Qty.
Recommended Slots
P < 2500 W
Non-
redundancy
1
PSU1
2500 W < P < 5000 W
Non-
redundancy
2
PSU1, PSU4
5000 W < P < 7500 W
Non-
redundancy
3
PSU1, PSU2, PSU4
7500 W < P < 10000 W
Non-
redundancy
4
PSU1, PSU2, PSU4, PSU5
10000 W < P < 12500 W
Non-
redundancy
5
PSU1, PSU2, PSU3,
PSU4, PSU5
12500 W < P < 15000 W
Non-
redundancy
6
PSU1, PSU2, PSU3,
PSU4, PSU5, PSU6
P < 2500 W
1+1
redundancy
2
PSU1, PSU4
E9000 Server
User Guide
2 Overview
Issue 25 (2019-11-30)
Copyright © Huawei Technologies Co., Ltd.
27