Table 2-5
Status description for the DC PSU operating status indicator
Color
Status and Meaning
Green
l
Steady: The PSU is running properly.
l
Blinking (at 0.5 Hz): The PSU is in hibernation and supplies no power.
Red
On: The PSU is not running properly.
NOTE
The causes are as follows:
l
The PSU is in input overvoltage or undervoltage state.
l
The PSU is in output overvoltage or undervoltage state.
l
The PSU is supplying no power.
l
A fan module alarm is generated, or a fan module fails.
Off
Off: No power is supplied.
2.5.4 PSU Configuration Policies
The power consumption of the E9000 varies depending on the system configuration. PSUs are
configured based on power consumption.
Maximum Power Consumption of Major Components
Table 2-6
Maximum power consumption of major components
Category
Component
Maximum Power
Consumption
Compute nodes
CH121
591 W
CH140
783 W
CH140 V3
763 W
CH220
777 W
CH221
777 W
CH222
613 W
CH225 V3
800 W
CH240
939 W
CH242
1089 W
CH242 V3
l
CH242 V3 8HDD: 1259
W
l
CH242 V3 4HDD: 1265
W
CH242 V3 DDR4
1312 W
E9000 Server
User Guide
2 Overview
Issue 25 (2019-11-30)
Copyright © Huawei Technologies Co., Ltd.
20