director product manager user guide
1–25
Product Manager Overview
Table 1–1: Operating Status—Status Bar and Director Status
Symbol
Alert Panel
Director Status
Table Text
Meaning
Green Circle
Fully Operational
All components and installed
ports are operational; no
failures.
Yellow Triangle
Redundant Failure
A redundant component has
failed, such as a power
supply, and the backup
component has taken over
operation.
Minor Failure
A failure occurred which has
decreased the director
operational ability. Normal
switching operations are not
affected.
•
One or more port cards
failed, but at least one port
card is still operational.
•
A fan has failed or is not
rotating sufficiently.
•
One of two CTP cards
failed.
•
One of two SBAR cards
failed.
Blinking Red
Diamond with
Yellow
Background
Not Operational
A critical failure prevents the
director from performing
fundamental switching
operations.
•
All fans fail.
•
Both SBAR cards fail.
•
All installed port cards fail.