4–6
director product manager user guide
Using Logs
— 0=Informational
— 2=Minor
— 3=Major
— 4=Severe (not operational)
•
FRU Position—An acronym representing the FRU type, followed by a number
representing the FRU chassis position. FRU acronyms are:
— BKPLNE—backplane.
— CTP—control processor (CTP) card.
— SBAR—serial crossbar (SBAR) card.
— Port—card.
— FAN—fan module.
— PWR—power supply.
The chassis (slot) position for a nonredundant FRU is 0. The chassis positions for
redundant FRUs are 0, 1, and 2. The chassis positions for port cards are
0 through 35, and slot 32 is unavailable.
•
Event Data—Up to 32 bytes of supplementary information for the event in
hexadecimal format. For detailed information on event data and problem
resolution, refer to the event code tables appendix in the hp StorageWorks director
2/64 service manual for the Director 2/64 and the hp StorageWorks director 2/140
service manual for the Director 2/140.
Hardware Log
The Hardware Log displays information on FRUs inserted and removed from the
director.