3–30
director product manager user guide
Configuring the Director
•
Tx Throughput—An alert will occur if the threshold set for transmit
throughput is reached.
•
Rx or Tx Throughput—An alert will occur if the threshold set for either
receive or transmit throughput is reached.
5. Click Next. A new screen displays with additional parameters, as shown in
Figure 3–16
. The name configured for the alert displays at the top of the screen.
NOTE: Click Previous if you need to return to the previous screen.
Figure 3–16: New Threshold Alerts dialog box—second screen
6. Enter a percentage from 1 through 100 for % utilization. When throughput
reaches this percentage of port capacity, a threshold alert will occur.
7. Enter the amount of cumulative minutes in which the % utilization should exist
during the notification interval before an alert is generated. You can also choose
At any time if you want an alert to occur whenever the set % utilization is
reached. The valid range is from 1 to the interval value set in
step 8
.
8. Enter the interval in minutes in which throughput is measured and threshold
notifications can occur. The valid range is 5 minutes to 70,560 minutes.