A–24
director product manager user guide
Information and Error Messages
Performing this
operation will
change the current
state to Offline.
This message
requests confirmation
to set the director
offline.
Click OK to set the director
offline or click Cancel to
cancel the operation.
Performing this
operation will
change the current
state to Online.
This message
requests confirmation
to set the director
online.
Click OK to set the director
online or click Cancel to
cancel the operation.
Periodic Date/Time
synchronization
must be cleared.
Action cannot be
performed because
Periodic Date/Time
Synchronization
option is active.
Click Periodic Date/Time
Synchronization check box
in Configure Date and Time
dialog box (Configure menu)
to clear check mark and
disable periodic date/time
synchronization.
Port binding was
removed from
attached devices
that are also
participating in
Switch Binding.
Informational
message. User has
removed Port Binding
from attached
devices, but one or
more of these
devices is still
controlled by Fabric
Binding.
Review the Switch Binding
Membership List to
determine if the devices
should be members.
Port cannot swap to
itself.
Port addresses
entered in the Swap
Ports dialog box are
the same.
Ensure that address in the
first and second port address
fields are different.
Port diagnostics
cannot be
performed on an
inactive port.
This displays when
port diagnostics is
run on a port in an
inactive state.
Run the diagnostics on an
active port.
Port speeds cannot
be configured at a
higher rate than the
director speed.
This displays when
you configure a port
to 2 Gb/sec and the
director speed is set
to 1 Gb/sec.
Set the director speed to 2
Gb/sec in the Configure
Operating Parameter dialog
box.
Table A–1: Product Manager Messages (Continued)
Message Description
Action