2–30
director product manager user guide
Monitoring and Managing the Director
— GSML—G_Port, short wave, multimode, LC connector, 1 Gigabit
— GXXL—G_Port, mixed mode, LC connector, 1 Gigabit
— FPM—G_Port, small form factor optics (SFO) pluggable, FICON port
module, 1 Gigabit.
— UPM—G_Port, small form factor optics (SFP) pluggable, FICON port
module, 2 Gigabit.
— GSFM—G_Port, short wave, single mode, MT-RJ connector, 1 Gigabit
— GLSR—G_Port, short wave, single mode, MT-RJ connector, 1 Gigabit
— GXXR—G_Port, mixed mode, MT-RJ connector, 1 Gigabit
— GXXL—G_Port, mixed mode, LC connector, 1 Gigabit
— FAN—Fan module.
— PWR—Power supply.
•
Position—A number representing the FRU chassis position. The chassis (slot)
position for a nonredundant FRU is 0. The chassis positions for redundant FRUs
are 0 and 1. The chassis positions for port cards are from 0-63 on the
Director 2/64, and 0-127 and 132-143 on the Director 2/140. Note that for the
Director 2/140, ports 128-131 are internal ports and not available for external
connections.
•
Status—The FRU status (Active or Backup).
•
Part Number—The FRU part number.
•
Serial Number— The FRU serial number.
Node List View
Display the Node List View in the View panel by choosing Node List from the view
tabs. This view displays information about all node attachments to any F_Ports on the
director sorted by port number. All data is dynamic and updates automatically as
devices log in and log out.