A–12
director product manager user guide
Information and Error Messages
Device applications
should be
terminated before
starting
diagnostics. Press
NEXT to continue.
Port diagnostics
(loopback tests)
cannot be performed
on a port while an
attached device
application is
running.
Terminate the device
application and perform
diagnostics again.
[device WWN]
cannot be removed
from the Switch
Membership List
while participating
in Switch Binding.
The device must be
isolated from the
switch, or Switch
Binding deactivated
before it can be
removed.
User attempted to
remove a device
WWN from the
Switch Membership
List (SANtegrity
feature) while Switch
Binding is enabled.
Remove the device from the
switch by blocking the port,
setting the switch offline, or
disabling Switch Binding
through the Switch Binding
Change State dialog box
before removing devices from
the Switch Membership
List.
Director clock alert
mode must be
cleared before
enabling period
synchronization.
Clock alert mode is
enabled through the
Configure FICON
Management Server
dialog box and user is
attempting to enable
Periodic Date/Time
Synchronization
through the
Configure Date and
Time dialog box.
Disable clock alert mode
through the Configure
FICON Management Server
dialog box.
Table A–1: Product Manager Messages (Continued)
Message Description
Action