RECLOSER CONTROL EVRC2A-N6,NT
http://www.entecene.co.kr
36
EN
HANCED
TEC
HNOLOGY
[LINE CURRENT(A)]
A: 0 B: 0
C: 0 G: 0
SG: 0 I2: 0
[ZERO SEQ CURRENT]
0 A 0.0 Lag
[POS SEQ CURRENT]
0 A 0.0 Lag
[NEG SEQ CURRENT]
0 A 0.0 Lag
[SENSTV CURRENT]
0 A 0.0 Lag
[PHASE C CURRENT]
0 A 0.0 Lag
[GROUND CURRENT]
0 A 0.0 Lag
[PHASE A CURRENT]
0 A 0.0 Lag
[PHASE B CURRENT]
0 A 0.0 Lag
RECLOSER CONTROL
EVERC2A-N6
LOOP CONTROL
ENTEC E&E CO. V6.05
EVRC2A - CURRENT (A)
A: 0 B: 0
C: 0 G: 0
SG: 0 I2: 0
EVR2A-SYSTEM STATUS
CONTROL : NOPANEL
BREAKER : OPEN
BAT:24.00 GAS:NOGAS
[MAIN MENU]
>1.SELECT SETBANK
2.PRIMARY SETTING
3.ALTERNATE SETTING
4.EDITBANK SETTING
5.STATUS
6.METERING
7.MAINTENANCE
8.EVENT RECORDER
[SETTING]
>1.RELAY SETUP
2.SYSTEM SETUP
3.PROTECTION
4.MONITORRING
5.SAVE SETTING
ALTERNATE
PRIMARY
EDITBANK
[SYSTEM SETUP]
>1.CURRENT SENSING
2.LINE VS SENSING
3.LINE VL SENSING
4.SYSTEM POWER
5.PANEL SLEEP TIME
6.OPTO INPUT SET
7.OUTPUT RELAY SET
8.LOOP CONTROL
9.SET GROUP CHANGE
10.POWER QUALITY
[PROTECTION]
>1.OPERATION
2.INTERVALS
3.PICKUP CURRENT
4.PHASE FAST
5.PHASE DELAY
6.GROUND FAST
7.GROUND DELAY
8.SEF ELEMENT
9.NEG SEQ FAST
10.NEG SEQ DELAY
11.H/C TRIP-PHA
12.H/C TRIP-GND
13.H/C TRIP-NEQ
14.H/C LOCKOUT-PHA
15.H/C LOCKOUT-GND
16.H/C LOCKOUT-NEQ
17.CLOD LOAD PICKUP
18.DIRECTION
19.VOLTAGE
20.FREQUENCY
21.OTHER ELEMENT
22.USER CURVE SET
23.LOSS OF PHASE
[MONITORING]
>1.DEMAND
2.SYNCHROCHECK
3.TRIP COUNTER
4.RECLOSER WEAR
5.BATTERY TEST
6.FAULT LOCATOR
7.GAS LOW LOCK
8.EXT
TRIP&LOCK
9.LIVE LOAD BLOCK
[COMMUNICATION]
>1.PROTOCOL SETUP
2.PORT SETUP
3.DIALUP MODEM-1
4.DIALUP MODEM-2
5.EVENT&ETC
[CLEAR SAVED DATA]
>1.Fault Cycle
2.System Status
3.Load Profile
4.Daignostic
5.Max Demand
6.Energy
7.Counter
8.Wear Monitor
9.Fault Trip
10.P-Quality Count
11.P-Quality Event
12.Comm
Event
13.ALL Saved data
[DIRECTION ELEMENT]
>1.PHASE DIRECTION
2.GROUND DIRECTION
3.SEF DIRECTION
4.NEQ DIRECTION
[VOLTAGE]
>1.UNDER VOLTAGE 1
2.UNDER VOLTAGE 2
3.OVER VOLTAGE 1
4.OVER VOLTAGE 2
[USER CURVE SET]
>1.USER CURVE 1
2.USER CURVE 2
3.USER CURVE 3
4.USER CURVE 4
[STATUS]
>1.OPTO INPUTS
2.RELAY OUTPUTS
3.CLOCK
4.CONTROL TYPE
[METERING]
>1.CURRENT
2.S-VOLTAGE
3.FREQUENCY
4.SYNCHRO VOLTAGE
5.POWER
6.ENERGY
7.DEMAND
8.SYSTEM
9.L-VOLTAGE
10.UNBALANCE
11.HARMONICS
[MAINTENANCE]
>1.COUNTERS
2.WEAR MONITOR
3.OUTPUT RELAY TEST
4.POWER QUALITY
[EVENT RECORDER]
>1.FAULT CYCLE
2.SYSTEM STATUS
3.LOAD PROFILE
4.DIAGNOSTIC
5.FAULT TRIP
6.POWER QUALITY
[RELAY SETUP]
>1.PASSCODE
2.COMMUNICATION
3.CLOCK
4.EVENT RECORDER
5.CLEAR SAVED DATA
6.FACTORY DEBUG
7.GAS SENSOR TYPE
8.TIME SET&DIS TYPE
Figure 3-12. Menu Structure Tree