13.7. User-Available DC Power
Table 13-1. User-Available DC Power
Voltage Rating
Voltage Range
Maximum Power output
Positions
24Vdc
20
∼
25Vdc
40W Continuous
60W 60second
Short 1second
Side Panel CN5
(1-VCC/+)
(2-AGND/-)
15Vdc
14.0
∼
15.5Vdc
12Vdc
11.0
∼
12.5Vdc
Standard Voltage : 12Vdc / User can select Voltage Rating
y
30W DC Power is provided. In case of the necessity of larger than 30W, additional power
should be attached. For more details, contact manufacturer. Input of the additional power is
referred to
“Figure 13-7. Terminal Block and Fuses”
y
Remove cable coating at the end of cable length of 8mm(0.315
"
). With using (
+
) CN5
connector terminal on side panel should be connected to Wire size AWG24 up to 12.
y
To change Voltage ratings, disconnect Jumper Pin in JP3
“Figure 13-31. ANALOG
BOARD”
, and connect Jumper Pin to either JPI (24Vdc) or JP2 (15Vdc). Be sure of the
voltage rating due to disassembly.
y
When overload, automatically circuit breaks current. In case long-term overload time, there
is a fuse on analog circuits to protect circuits from failure.