3.5 Remote Controller for Hotel Use <BRC3A61>
69
Remote Controllers
3.5
Remote Controller for Hotel Use <BRC3A61>
(NOTE)
· For the sake of explanation, all indications are shown in the figure above contrary to actual running situations.
· This remote controller does not have "AIR FLOW DIRECTION ADJUST BUTTON".
Don't operate the flap adjusting air flow direction by your hand.
(FXF(Q), FXC(Q), FXH(Q), FXA(Q), FXK(Q))
This display shows that the total heat exchange are
in operation.
(This is optional accessory)
Indicates malfunction and blinks if the unit stops
operating due to malfunction.
(As for details. see "TROUBLE SHOOTING" in the
operation manual attached to the indoor uint or the
outdoor unit.)
DISPLAY " OPTION" (VENTILATION /
AIR CLEANING)
DISPLAY " " " " " " " " " "
(OPERATION MODE)
4
FAN SPEED CONTROL BUTTON
DISPLAY " " (DEFROST/HOT START)
When this display shows, the system is UNDER
CENTRALIZED CONTROL
(This is not a standard specification)
8
DISPLAY " " (MALFUNCTION)
11
1
7
REMOTE CONTROLLER: NAME AND FUNCTION OF EACH SWITCH AND DISPLAY
10
OPERATION LAMP (RED)
DISPLAY " " (FAN SPEED)
DISPLAY " " (SET TEMPERATURE)
2
3
TEMPERATURE SETTING BUTTON
Press the button and the system will start.
Press the button again and the system will stop.
DISPLAY " " (UNDER CENTRALIZED
CONTROL)
6
5
BRC3A61
11
Press this button to select the fan speed, HIGHT or LOW,
of your choice.
The display shows the fan speed: "HIGH" or "LOW".
4
This display shows current OPERATION MODE.
" " is not available with outdoor units specially
designed for cooling only.
" " is reserved only for outdoor units capable of heat
recovery.
Use this button for SETTING TEMPERATURE of the
thermostat.
: Each press raises the set temperature by 1˚C
: Each press lowers the set temperature by 1˚C
The variable temperature range is 16˚C to 32˚C.
5
ON/OFF BUTTON
8
This display shows the set temperature.
Only given during a cooling or heating operation.
1
2
9
The lamp lights up during operation.
Blinks in case of stop due to malfunction.
Indicates that defrost or hot start (during which the fan is
stopped till the temperature of air supply rises enough at
the start of a heating run) is progress.
3
10
7
6
3PA61137
Summary of Contents for D-BACS
Page 1: ...ED 72 721 Preliminary Daikin Buildings Air conditioning Control System D BACS DESIGN GUIDE ...
Page 17: ...xvi 1 5 Open Network Glossary Introduction ...
Page 41: ...24 Outline of D BACS System ...
Page 74: ...57 Remote Controllers HRV Wired remote controller BRC301B61 VAM ...
Page 107: ...90 5 4 HRV BRC301B61 Remote Controllers ...
Page 142: ...1 2 System Configuration 125 Control Devices 1 2 System Configuration System Outline ...
Page 181: ...164 3 8 Error Diagnosing Function Control Devices ...
Page 215: ...198 3 8 Wiring Example intelligent Manager ...
Page 235: ...218 Interface for Use in BACnet ...
Page 253: ...236 Interface for use in LONWORKS 10 Reference Materials Error Code Conversion Table ...
Page 268: ...251 Interface for use in LONWORKS 13 Workflow ...
Page 285: ...268 1 6 Notes Power Proportional Distribution P P D ...