14
Outline of D-BACS System
4. List of Control System Equipment and Functions
Control
Monitoring
Other controls
Type
Number of
controllable indoor
units for each
controller
ON/
O
F
F
Tem
p
erat
ur
e se
tt
ing
Cool
/heat
changeo
ver
Rem
o
te
cont
rol
accept
ance/
rej
e
ct
io
n
Ai
r fl
o
w
r
a
te
se
ttin
g
A
ir
f
lo
w
di
rec
ti
on s
et
ti
ng
Force
d
t
herm
o
s
tat
OFF
Week
ly
sc
hedul
e c
ont
ro
l
ON/
O
F
F
s
tat
us
E
rror
M
al
funct
ion c
ode
Indoor t
em
perat
ure
Fi
lt
er si
gn
P
o
we
r e
sti
m
a
ti
o
n
S
tat
us
out
put
w
it
h t
herm
ost
at
ON
Fan st
at
us out
p
ut
Wi
tho
ut
rem
ot
e cont
rol
ler
Zone cont
rol
Force
d
OFF
by ext
ernal
c
ont
ac
t
ON/
O
F
F
b
y
ex
te
rn
al
cont
act
Dem
and cont
ro
l
Low
operat
ing noi
se
cont
rol
intelligent Manager
III
1024 groups
z z z z z z
—
z z z z z z z
—
z z z z
*1
z z
×
LONWORKS
®
64 groups
z z z z z z z
—
z z z z z
—
z
—
z
—
z
— — —
BACnet
®
256 groups
z z z z z z z
—
z z z z z z
*2
z z z
×
z
×
×
×
Parallel interface
16 groups
z z
×
z
×
×
×
×
z z
×
z z
× ×
×
×
×
z z
×
×
intelligent Touch
Controller
128 groups
*3
z z z z z z
×
z z z z z z z
*2
×
×
z z z
×
×
×
Central remote
controller
64 groups
z z z z
▲ ▲
×
×
z z z
×
z
× ×
×
z z z
×
×
×
Unified ON/OFF
controller
16 groups
z
×
×
z
×
×
×
×
z z
— — — — — — — —
z
— — —
Schedule timer
128 groups
z
×
×
z
×
×
×
z
× ×
×
×
×
× ×
×
×
×
× ×
×
×
Wired Remote
Controller
—
z z z
×
z z
×
×
z z z z z
× ×
×
×
×
× ×
×
×
Wireless Remote
Controller
—
z z z
×
z z
×
×
z z z z z
× ×
×
×
×
× ×
×
×
Simplified Remote
Controller
—
z z z
×
z
— ×
×
z z z z
×
× ×
×
×
×
× ×
×
×
Remote Controller
for Hotel Use
—
z z z
×
z
— ×
×
z z z z
×
× ×
×
×
×
× ×
×
×
Wired Remote
Controller with Weekly
Schedule Timer
—
z z z
×
z z
×
z z z z z z
× ×
×
×
×
× ×
×
×
Interface adaptor
for SkyAir series
—
z z z z
▲
*5
▲
*5
▲
*4
×
▲
*5
▲
*5
z
▲
*6
z
×
▲
*7
▲
*4
z
— × ×
×
×
Interface adaptor
for DIII-NET(RA)
—
z z
×
z
×
× — ×
z z z z
×
× ×
×
×
z
× ×
× —
Wiring adaptor for
other air conditioners
—
z
×
×
× ×
×
×
×
×
z
×
×
×
× ×
× — — — × — —
Di, Dio unit
—
z
*8
×
×
× ×
×
×
×
z z
×
×
×
× ×
×
×
×
× ×
×
×
Unification adaptor for
computerized control
—
— — — — — — — —
z z
— — — — — — — — —
z
— —
Wiring adaptor for
electrical appendices (2)
16 units
z z
×
z
×
×
×
×
z z
— — — — — — — —
z z z
—
Wiring adaptor for
electrical appendices (1)
64 groups
z z
×
z
×
×
z
×
z z
— — — — — — — —
z z z
—
Adaptor for wiring
1 unit
— — — — — — — — — — — — — —
z z
— — — — — —
External control adaptor
for outdoor unit
10 units
(Outdoor unit)
×
×
z
× ×
×
×
× — — — — — — — — — — — —
z z
z
: Possible
*1 "Emergency Stop" function is possible.
*2 Optional accessory is required.
*3 Possible when DIII-NET PLUS adaptor are used in combination. If not, 64 groups.
*4 OFF when interlocked with BACnet
®
.
*5 Possible from central control equipment (i.e., intelligent Touch Controller,
LONWORKS
®
, BACnet
®
, or Unified ON/OFF Controller)
*6 Possible with parallel interface.
*7 Possible with BACnet
®
or LONWORKS
®
.
*8 Dio unit only.
▲
: Possible under condition
× : Impossible
— : Outside the application
Summary of Contents for D-BACS
Page 1: ...ED 72 721 Preliminary Daikin Buildings Air conditioning Control System D BACS DESIGN GUIDE ...
Page 17: ...xvi 1 5 Open Network Glossary Introduction ...
Page 41: ...24 Outline of D BACS System ...
Page 74: ...57 Remote Controllers HRV Wired remote controller BRC301B61 VAM ...
Page 107: ...90 5 4 HRV BRC301B61 Remote Controllers ...
Page 142: ...1 2 System Configuration 125 Control Devices 1 2 System Configuration System Outline ...
Page 181: ...164 3 8 Error Diagnosing Function Control Devices ...
Page 215: ...198 3 8 Wiring Example intelligent Manager ...
Page 235: ...218 Interface for Use in BACnet ...
Page 253: ...236 Interface for use in LONWORKS 10 Reference Materials Error Code Conversion Table ...
Page 268: ...251 Interface for use in LONWORKS 13 Workflow ...
Page 285: ...268 1 6 Notes Power Proportional Distribution P P D ...