BAT32G1x9 user manual | Chapter 22 CAN control
901 / 1149
Rev.1.02
22.7.11
CAN Module Interrupt Enable Register (CnIE).
CnIE registers are used to enable or disable interrupts to the CAN module.
Figure 22-34. CAN
Module Interrupt Enable Register Format
(CnIE) (1/2
).
(a) read
(b) write
(a) read
CIE5-CIE0
CAN module interrupt enable bit
0
The interrupt output corresponding to the cnINTS [5:0] bit of the interrupt status
register is disabled
1
The interrupt output corresponding to the cnINTS [5:0] bit of the interrupt status
register is enabled
(b) write
SetCIE5
ClearCIE5
Set the CIE5
bit
0
1
CIE5 clear
0
1
0
CIE5 set
1
Other values
CIE5 has not changed
SetCIE4
ClearCIE4
Set the CIE4
bit
0
1
CIE4 bit clear 0
1
0
CIE4 Position 1
Other values
CIE4 has not changed