![Cmsemicon BAT32G1 9 Series User Manual Download Page 497](http://html1.mh-extra.com/html/cmsemicon/bat32g1-9-series/bat32g1-9-series_user-manual_2627609497.webp)
BAT32G1x9 user manual | Chapter 15 A/D converter
497 / 1149
Rev.1.02
○2 channel scan mode (ADM1. ADMD=1)
ADISS
ADS[4:0]
Analog input channel
Scan 0
Scan 1
1'b0
5'h00
ANI0
ANI1
1'b0
5'h01
ANI1
ANI2
1'b0
5'h02
ANI2
ANI3
1'b0
5'h03
ANI3
ANI4
1'b0
5'h04
ANI4
ANI5
1'b0
5'h05
ANI5
ANI6
1'b0
5'h06
ANI6
ANI7
1'b0
5'h07
ANI7
ANI8
1'b0
5'h08
ANI8
ANI9
1'b0
5'h09
ANI9
ANI10
1'b0
5'h0A
ANI10
ANI11
1'b0
5'h0B
ANI11
ANI12
1'b0
5'h0C
ANI12
ANI13
1'b0
5'h0D
ANI13
ANI14
1'b0
5'h0E
ANI14
ANI15
Other than the above
Prohibit settings.
Note:
1. When scanning mode, bit4, bit5 and bit6 must be set to "0".
2In the pin set by the PMCx register as the analog input, the A/D conversion can be specified as the analog input by the
ADS.
3. Pins that are set to digital inputs/outputs by pin mode control registers (PMCxx) cannot be set through ADS registers.
4. To override the ADISS bit, it must be done in the transition stop state (ADCS=0, ADCE=0).
5. When USing AVREFP as the positive (+) reference voltage for an A/D converter, ANI0 cannot be selected as the A/D
conversion channel.
6. When USing AVREFM as the negative (
–) reference voltage for an A/D converter, ANI1 cannot be selected as the A/D
conversion channel.
7. After placing the ADISS position "1", the conversion result of the first time cannot be used. For a detailed setup
procedure, refer to "15.5.4Settings when selecting the output voltage/internal reference voltage of the temperature sensor".
8. When you want to move to deep sleep mode or to sleep mode while the CPU is running at the subsystem clock, you
cannot place the ADISS position "1".