BAT32G1x9 user manual | Chapter 23 LCD bus interface
1007 / 1149
Rev.1.02
(6). LCD bus transmission
•
Use S1D15E00 (EPSON
).
Data/commands transmitted via DMA should be stored in advance in the RAM address. For example, the
settings are as follows. Please refer to the S1D15E00 data sheet for details of the command.
The RAM address value
command
description
0x20001000
A0H
ADC select
SEG0→SEG131:
0(H) → column addresses →83(H).
LCD driver
initialization
(S1D15E0).
0x20001001
C0H
Universal Output Mode Selection
COM Normal Scan Direction, COM0 → COM95
0x20001002
A6H
Normal display/reverse display
RAM data: High potential (normal) when lcd on
0x20001003
A4H
Displays all points on/off
Normal display mode
0x20001004
61H
Duty cycle setting (2 byte).
Set the duty cycle to 1/8 and the starting point of the block to 0
(COM0 to 3).
0x20001005
00H
0x20001006
81H
Electrical parameters (2 byte).
Set the electrical parameter register 05H (small).
0x20001007
05H
0x20001008
40H
Temperature gradient settings
Set the temperature gradient to 0.06%/°C
0x20001009
8AH
Displays the starting row setting (2 byte).
Set the display start line to 0
Displays the settings
0x2000100A
00H
0x2000100B
B0H
Set the page address
The page address is set to 0
0x2000100C
10AM
Set the column address
The high 4 bits displayed are 0000B, and the low 4 bits are
the default (0000B).
0x2000100D
7FH
Write the displayed data
The displayed data is:
"E"
0x2000100E
49H
0x2000100F
49H
0x20001010
49H
0x20001011
41H
0x20001012
AFH
Turn on display
Displays Startup