BAT32G1x9 user manual | Chapter 19 Universal serial communication unit
612 / 1149
Rev.1.02
(3) Process flow (single receive mode).
Figure 19-34
Timing diagram of the master receive (single receive mode) (type 1: DAPmn = 0, CKPmn = 0).
SCLKp pin
SDIp pin
INTSSPIp
shift register mn
TSFmn
SDRmn
SEmn
STmn
SSmn
virtual data used for receiving
virtual data
virtual data
Receiving&shift operation
Receiving&shift operation1
data reception
data reception
data reception1
data reception2
data reception3
Receiving&shift operation
data reception
data reception1
data reception2
data reception3
Read
Write
Read
Write
Read
Write
Remark
m: unit number (m=0
~
2) n: channel number (n=0
~
3) p: SSPI number (p=00, 01, 10, 11, 20, 21, 30,
31)
mn=00
~
03, 10
~
11, 20
~
21