Service Mode > COPIER > OPTION > IMG-FIX
Service Mode > COPIER > OPTION > IMG-FIX
COPIER > OPTION > IMG-FIX
FXS-TMP2
Img form start temp: heavy ppr, 1/2 SPD
Lv.1 Details
To set the offset of image formation start temperature and 2-step
startup judgment temperature for heavy paper/extra-long heavy paper
at 1/2 speed.
As the value is incremented by 1, the control temperature is increased
by 5 deg C.
Use case
- When a fixing failure occurs at the leading edge of paper
- When uneven gloss occurs in the area that is 76 mm from the
leading edge
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
FXS-TMP3
[Not used]
Lv.1 Details
-
FXS-TMP4
Img form start temp: plain ppr, 1/2 SPD
Lv.1 Details
To set the offset of image formation start temperature and 2-step
startup judgment temperature for plain paper (including thin paper,
plain paper 2 and plain paper 3) at 1/2 speed.
As the value is incremented by 1, the control temperature is increased
by 5 deg C.
Use case
- When a fixing failure occurs at the leading edge of paper
- When uneven gloss occurs in the area that is 76 mm from the
leading edge
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
FXS-TMP5
Image formation start temp: transparency
Lv.1 Details
To set the offset of image formation start temperature for transparency.
As the value is incremented by 1, the control temperature is increased
by 5 deg C.
Use case
- When a fixing failure occurs at the leading edge of paper
- When uneven gloss occurs in the area that is 76 mm from the
leading edge
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
COPIER > OPTION > IMG-FIX
FXS-TMP6
Image formation start temp: envelope
Lv.1 Details
To set the offset of image formation start temperature for envelope at
1/1 and 1/2 speed.
As the value is incremented by 1, the control temperature is increased
by 5 deg C.
Use case
- When a fixing failure occurs at the leading edge of paper
- When uneven gloss occurs in the area that is 76 mm from the
leading edge
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
FLYING
ON/OFF of flying start temperature ctrl
Lv.2 Details
To set ON/OFF of flying start temperature control.
When “1” is set, the flying start temperature control is not executed.
This is more life-conscious for Fixing Assembly compared to “0”.
Use case
When preferring to extend the life of Fixing Assembly. However,
setting of “1” does not mean that the life of Fixing Assembly is always
extended.
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
When “1” is set, FCOT/FPOT is reduced.
Display/adj/set range
0 to 1
0: ON, 1: OFF
Default value
0
DMX-OF-Y
Adjustment of Y-color D-max target density
Lv.2 Details
To adjust the target density of D-max control in case that density of
solid area on Y-color image is not appropriate even performing auto
gradation adjustment.
Increase the value when the density is low and decrease the value
when the density is high.
Use case
When density of solid area is not appropriate even performing auto
gradation adjustment
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
3) Execute full adjustment of auto gradation adjustment.
Display/adj/set range
-3 to 3
Default value
0