Service Mode > COPIER > DISPLAY > HT-C
Service Mode > COPIER > DISPLAY > HT-C
COPIER > DISPLAY > HT-C
DLTA-B-Y
Display of ARCDAT screen B Y-density differ
Lv.2 Details
To display the difference between the Y-patch target value and the
current value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
Default value
0
DLTA-B-M
Display of ARCDAT screen B M-density differ
Lv.2 Details
To display the difference between the M-patch target value and the
current value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
Default value
0
DLTA-B-C
Display of ARCDAT screen B C-density differ
Lv.2 Details
To display the difference between the C-patch target value and the
current value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
Default value
0
DLTA-B-K
Display of ARCDAT screen B Bk-density differ
Lv.2 Details
To display the difference between the Bk-patch target value and the
current value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
Default value
0
COPIER > DISPLAY > HT-C
DLTA-C-Y
Display of ARCDAT screen C Y-density differ
Lv.2 Details
To display the difference between the Y-patch target value and the
current value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
Default value
0
DLTA-C-M
Display of ARCDAT screen C M-density differ
Lv.2 Details
To display the difference between the M-patch target value and the
current value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
Default value
0
DLTA-C-C
Display of ARCDAT screen C C-density differ
Lv.2 Details
To display the difference between the C-patch target value and the
current value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
Default value
0
DLTA-C-K
Display of ARCDAT screen C Bk-density differ
Lv.2 Details
To display the difference between the Bk-patch target value and the
current value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
Default value
0
TGT-A-Y2
[Not used]
TGT-A-M2
[Not used]
TGT-A-C2
[Not used]
TGT-A-K2
[Not used]
TGT-B-Y2
[Not used]
TGT-B-M2
[Not used]