![Canon imageRUNNER ADVANCE C2030 Service Manual Download Page 313](http://html2.mh-extra.com/html/canon/imagerunner-advance-c2030/imagerunner-advance-c2030_service-manual_3056452313.webp)
4
4
4-65
4-65
Parts Replacement and Cleaning > Disassembly/Assembly - Image Formation System - > Removing the Hopper Unit (CL)
Parts Replacement and Cleaning > Disassembly/Assembly - Image Formation System - > Removing the Hopper Unit (CL)
Points to Note at Installation:
1) Be sure to check the position of the Toggle Lever when installing the Toner Bottle
Mount.
(If the Toggle Lever is not in the correct position, the Toner Bottle cannot be installed.)
2) Be sure to route the harness along the guide of the Toner Bottle Mount without slack
for not blocking the laser light path.
3) After installing the Link Lever, check that the Toner Bottle Door Unit opens and closes
smoothly.
4) After installation, check if the cover of Drum Unit opens and closes.
F-4-108
F-4-109
Removing the Hopper Unit (CL)
Preparation
1) Remove the all Drum Units.
2) Remove the ITB Unit.
3) Turn OFF the power.
4) Remove the Cassette 1.
5) Remove the Front Cover.
6) Remove the Left Cover.
7) Remove the First Delivery Tray.
8) Remove the Toner Bottle Mount of the target color.
Procedure
NOTE:
In this procedure, procedure for the Hopper Unit (M) is described. Be sure to perform
the same procedure for (Y) and (C).
1) Remove the stopper and remove the Link Stick in the direction of the arrow.
• 1 Claw
F-4-110