![Canon imageRUNNER ADVANCE C2030 Service Manual Download Page 665](http://html2.mh-extra.com/html/canon/imagerunner-advance-c2030/imagerunner-advance-c2030_service-manual_3056452665.webp)
8
8
8-113
8-113
Service Mode > COPIER > OPTION > FNC-SW
Service Mode > COPIER > OPTION > FNC-SW
COPIER > OPTION > FNC-SW
CPR-SW
Clr displc crrct frqcy adj:temp chng
Lv.1 Details
If a specific temperature change is seen from the previous control, the
color displacement correction control is executed again.
By changing this temperature variation range, the frequency of
executing the color displacement correction control is set.
Usually, set “0” which balances image quality and productivity.
When 1 is set, the temperature variation range becomes narrowed, so
the frequency of executing the color displacement correction control is
increased. The color displacement can be reduced, but the downtime
is increased.
When 2 is set, the temperature variation range becomes widened, so
the frequency of executing the color displacement correction control is
decreased. The downtime can be reduced, but the color displacement
occurs.
Use case
- When preventing the color displacement due to a temperature
change
- When preventing an increase in downtime due to a temperature
change
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to get approval from the user by telling that the downtime is
increased if image quality is prioritized, and the color displacement is
increased if productivity is prioritized.
Display/adj/set range
0 to 2
0: Normal, 1: Quality priority, 2: Productivity priority
Default value
0
DMAX-DAY
D-max exe frqcy switch ON/OFF
Lv.1 Details
To set whether to switch the frequency to execute the D-max control
after a specified number of sheets is fed.
Set 1 when increasing the frequency to execute D-max control after
making a large number of outputs.
Use case
When density varies at the time of making a large number of outputs
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
COPIER > OPTION > FNC-SW
JM-ERR-D
Handling 0CAx jam as an error: DCON
Lv.2 Details
To display 0CAx jam as the error E996-0CAx.
By handling the jam as an error, the machine stops, so that loss of the
log can be prevented.
Be sure to enable the service mode at the user's site where 0CAx jam
occurs.
After that, if the error E996-0CAx occurs, the log which has been
backed up can be obtained.
Use case
When obtaining a log at the occurrence of 0CAx jam
Adj/set/operate method 1) Enter the setting value, and then press OK key.
Display/adj/set range
0: Display as a jam, 1: Display as an error
Default value
0
T-8-38