2
2
2-177
2-177
Process/Operation > Embedded RDS > E-RDS Setup > E-RDS-related setting items (service mode)
Process/Operation > Embedded RDS > E-RDS Setup > E-RDS-related setting items (service mode)
■
E-RDS-related setting items (service mode)
●
E-RDS setting items
Item
Description
E-RDS
([Lv.1] COPIER > Function > INSTALL)
Set use/ no use of Embedded-RDS function
0: Function not used / 1: Function used
e-Maintenance/ imageWARE Remote system to send
device information, counter data, error statuses to the
UGW.
Note that the operation (such as global click counter, error
information, etc.) can be restricted with the server settings.
Default : 0 (Function not used)
RGW-ADR
([Lv.1] COPIER > Function > INSTALL)
URL setting of UGW
Max 128 characters
Default : https://a01.ugwdevice.net/ugw/agentif01
RGW-PORT
([Lv.1] COPIER > Function > INSTALL)
Set port number of UGW
Validation : 1 to 65535
Default : 443
COM-TEST
([Lv.1] COPIER > Function > INSTALL)
Execution of a communication test with UGW / Display of
the result
Perform Communication test with UGW and set "OK!" or
"NG!" as the result.
COM-LOG
([Lv.1] COPIER > Function > INSTALL)
Display of detailed information about a communication error
with UGW
Error information of a connection failure with UGW is
displayed.
Error occurrence date and time, error code, and detailed
error information are displayed.
Max 30 latest loggings retained
Max 128 characters for Error information.
ERDS-DAT
([Lv.1] COPIER > Function > CLEAR)
Initialization of E-RDS SRAM data
SRAM data of E-RDS is initialized and returned to the
factory setting value at shipment.
CA-KEY
([Lv.2] COPIER > Function > CLEAR)
Initialization of CA certificate
When the power is turned OFF/ ON after execution, the CA
certificate in the factory setting is automatically installed.
T-2-93
●
SERVICE CALL BUTTON setting items
Item
Description
SCALL-SW
([Lv.1] COPIER > Option > USER)
Display/ hide of Service Call button
0: Hide / 1: Display
To set whether to display or hide the Service Call button on
the Control Panel.
Default : 0 (Hide)
SCALLCMP
([Lv.1] COPIER > Option > USER)
Set of service call completion notice
When this item is set, service call completion is notified
to UGW and the service call status retained internally is
cleared.
Default : 0
●
SERVICE BROWSER setting items
Item
Description
BRWS-ACT
([Lv.1] COPIER > Function > INSTALL)
Execution of activation/ inactivation of service browsing
Browsing info is sent to UGW when OFF (BRWS-ACT=0) is
changed to ACTIVE.
Setting result is displayed as "OK!" or "NG!".
BRWS-STS
([Lv.1] COPIER > Display > USER)
Display of Service Browser use status
0: OFF / 1: Active / 2: Suspend
The status is changed from 0 to 1, from 1 to 2, and from 2
to 1 by execution of BRWS-ACT.
Default : 0 (OFF)
NOTE:
Generally, once service browsing is enabled, it cannot be disabled again.
To disable service browsing, clear SRAM.
T-2-94
T-2-95