![Canon imageRUNNER ADVANCE C2030 Service Manual Download Page 593](http://html2.mh-extra.com/html/canon/imagerunner-advance-c2030/imagerunner-advance-c2030_service-manual_3056452593.webp)
8
8
8-41
8-41
Service Mode > COPIER > IO > Main Device (DCON > P001 to P016)
Service Mode > COPIER > IO > Main Device (DCON > P001 to P016)
Address bit
Name
Mark
0
1
P009
0 LIVEWAKE signal
1 Controller reset signal
2 P0 signal
3 CST 1 Paper Sensor
PS13
no paper
paper
4 CST 2 Paper Sensor
PS14
paper
no paper
5 Right Lower Cover Sensor
PS35
open
close
6 CST Right Upper Cover Open/Close
Detection Switch
SW18
close
open
7 Front Cover Sensor
PS34
open
close
8
9
10
11
12
13
14
15
P010
0 Developing Assembly (Y) Screw Rotation
Interruption Signal
1 Developing Assembly (M) Screw Rotation
Interruption Signal
2 Developing Assembly (C) Screw Rotation
Interruption Signal
3 Developing Assembly (Bk) Screw Rotation
Interruption Signal
4 Multi-purpose Tray Last Paper Sensor
PS11
no paper
paper
5 Multi-purpose Tray Paper Sensor
PS10
paper
no paper
6 Finisher Communication Line enable detection
7 Waste Toner Full Sensor
SW16
detect
8 Inner Finisher detection signal
detect
9 3 Way Unit detection signal
detect
10 Pedestal detection signal
detect
11 Cassette Pedestal ready signal
Ready
12 Toner Bottle Switch (Y)
SW08
detect
13 Toner Bottle Switch (M)
SW09
detect
14 Toner Bottle Switch (C)
SW10
detect
15 Toner Bottle Switch (Bk)
SW11
detect
Address bit
Name
Mark
0
1
P011
0 Toner Supply Motor (Y)
M06
OFF
ON
1 Toner Bottle Motor (Y)
M07
OFF
ON
2 Toner Supply Motor (M)
M08
OFF
ON
3 Toner Bottle Motor (M)
M09
OFF
ON
4 Toner Supply Motor (C)
M10
OFF
ON
5 Toner Bottle Motor (C)
M11
OFF
ON
6 Toner Supply Motor (Bk)
M12
OFF
ON
7 Toner Bottle Motor (Bk)
M13
OFF
ON
8
9
10
11
12
13
14
15
P012
0 DDI_LPPRDY
1 Inner Finisher download enable
2 Inner Finisher download mode settings
3
4 Cassette Pedestal reset signal
5 Inner Finisher Communication Line enable
6 Inner Finisher Controller reset
7
8 CST 2 Pickup Motor_I1
I0:I1= 00:100% 01:70% 10:30%
11:0%
9 CST 2 Pickup Motor_I0
10 Fixing Outlet Motor_I1
I0:I1= 00:100% 01:70% 10:30%
11:0%
11 Fixing Outlet Motor_I0
12 Second Delivery Motor_I1
I0:I1= 00:100% 01:70% 10:30%
11:0%
13 Second Delivery Motor_I0
14 Third Delivery Motor_I1
I0:I1= 00:100% 01:70% 10:30%
11:0%
15 Third Delivery Motor_I0