![Canon imageRUNNER ADVANCE C2030 Service Manual Download Page 585](http://html2.mh-extra.com/html/canon/imagerunner-advance-c2030/imagerunner-advance-c2030_service-manual_3056452585.webp)
8
8
8-33
8-33
Service Mode > COPIER > DISPLAY > HT-C
Service Mode > COPIER > DISPLAY > HT-C
COPIER > DISPLAY > MISC
LPOWER-M
Display of laser power (M)
Lv.2 Details
To display the M laser power at the latest output.
The value is determined by D-max control.
Use case
When analyzing the cause of image failure (low density, ghost, etc.)
Display/adj/set range
0 to 255
LPOWER-C
Display of laser power (C)
Lv.2 Details
To display the C laser power at the latest output.
The value is determined by D-max control.
Use case
When analyzing the cause of image failure (low density, ghost, etc.)
Display/adj/set range
0 to 255
LPOWER-K
Display of laser power (Bk)
Lv.2 Details
To display the Bk laser power at the latest output.
The value is determined by D-max control.
Use case
When analyzing the cause of image failure (low density, ghost, etc.)
Display/adj/set range
0 to 255
■
HT-C
COPIER > DISPLAY > HT-C
TGT-A-Y
Display of ARCDAT screen A Y-color target VL
Lv.2 Details
To display the Y-patch target value of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-A-M
Display of ARCDAT screen A M-color target VL
Lv.2 Details
To display the M-patch target value of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
Default value
255
TGT-A-C
Display of ARCDAT screen A C-color target VL
Lv.2 Details
To display the C-patch target value of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
Default value
255
T-8-10
COPIER > DISPLAY > HT-C
TGT-A-K
Display of ARCDAT screen A Bk-clr target VL
Lv.2 Details
To display the Bk-patch target value of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
Default value
255
TGT-B-Y
Display of ARCDAT screen B Y-color target VL
Lv.2 Details
To display the Y-patch target value of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
Default value
255
TGT-B-M
Display of ARCDAT screen B M-color target VL
Lv.2 Details
To display the M-patch target value of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
Default value
255
TGT-B-C
Display of ARCDAT screen B C-color target VL
Lv.2 Details
To display the C-patch target value of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
Default value
255
TGT-B-K
Display of ARCDAT screen B Bk-clr target VL
Lv.2 Details
To display the Bk-patch target value of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
Default value
255