![Canon imageRUNNER ADVANCE C2030 Service Manual Download Page 511](http://html2.mh-extra.com/html/canon/imagerunner-advance-c2030/imagerunner-advance-c2030_service-manual_3056452511.webp)
7
7
7-37
7-37
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
E
Code
Detail
Code
Location
Item
Description
E532 0002 05
Title
STP Move Motor fails to return to HP
Description At initial rotation, when the Motor rotates for specified period
of time and cannot return to HP, it is detected as an error if the
same symptom occurs again after the first retry.
Remedy
1. Check the conditions of the parts around the Staple.
2. Check if the Motor (M1) Connector is physically removed.
3. Replace the Motor.
4. Check if the Stapler Move HP Sensor (S10) Connector is
physically removed.
5. Replace the Stapler Move HP Sensor (S10).
E540 0001 05
Title
Tray Lift Motor timeout error
Description Unable to complete the operation even after the specified
period of time during initial rotation. When the Motor remains
in the same area for the specified period of time and the same
symptom occurs again after the first retry, it is detected as an
error.
Remedy
1. Check if the Motor (M11) Connector is physically removed.
2. Replace the Motor failure occurs.
3. Check if the Stack Tray Clock Sensor (S14) Connector is
physically removed.
4. Replace the Stack Tray Clock Sensor (S14).
E540 0002 05
Title
Tray Lift Motor clock error
Description At initial rotation, when the Tray Lift Motor rotates and clock
input is not detected within the specified period of time, it is
detected as an error if the same symptom occurs again after the
first retry.
Remedy
1. Check if the Motor (M11) Connector is physically removed.
2. Replace the Motor.
3. Check if the Stack Tray Clock Sensor (S14) Connector is
physically removed.
4. Replace the Stack Tray Clock Sensor (S14).
E542 0001 05
Title
Additional Tray Lift Motor timeout error
Description Unable to complete the operation even after the specified
period of time during initial rotation. When the Motor remains
in the same area for the specified period of time and the same
symptom occurs again after the first retry, it is detected as an
error.
Remedy
1. Check if the Motor (M12) Connector is physically removed.
2. Replace the Motor.
3. Check if the Additional Tray Clock Sensor (S23) Connector is
physically removed.
4. Replace the Additional Tray Clock Sensor (S23).
E
Code
Detail
Code
Location
Item
Description
E542 0005 05
Title
Additional Tray Lift Motor clock error
Description At initial rotation, when the Tray Lift Motor rotates and clock
signal is not detected within the specified period of time, it is
detected as an error if the same symptom occurs again after the
first retry.
Remedy
1. Check if the Motor (M12) Connector is physically removed.
2. Replace the Motor.
3. Check if the Additional Tray Clock Sensor (S23) Connector is
physically removed.
4. Replace the Additional Tray Clock Sensor (S23).
E551 8001 05
Title
Front Fan lock error
Description While the front fan is rotating, this machine stops the front fan
after detecting the lock signal.
Then this machine retries to rotate the front fan, but lock signal
is detected again, this machine displays the error.
Remedy
1. Check the Fan (M8).
2. Replace the finisher controller PCB.
E551 8002 05
Title
Rear Fan lock error
Description While the rear fan is rotating, this machine stops the front fan
after detecting the lock signal.
Then this machine retries to rotate the rear fan, but lock signal
is detected again, this machine displays the error.
Remedy
1. Check the Fan (M9).
2. Replace the finisher controller PCB.
E567 0001 05
Title
Entrance Roller Release/Stopper HP Motor fails to move from
HP
Description At initial rotation, when the Motor rotates for specified period of
time and cannot move from HP, it is detected as an error if the
same symptom occurs again after the first retry.
Remedy
1. Check if the Motor (M6) Connector is physically removed.
2. Replace the Motor.
3. Check if the Entrance Roller Release/Stopper HP Sensor (S5)
Connector is physically removed.
4. Replace the Entrance Roller Release/Stopper HP Sensor
(S5).
E567 0002 05
Title
Entrance Roller Release/Stopper HP Motor fails to return to HP
Description At initial rotation, when the Motor rotates for specified period
of time and cannot return to HP, it is detected as an error if the
same symptom occurs again after the first retry.
Remedy
1. Check if the Motor (M6) Connector is physically removed.
2. Replace the Motor.
3. Check if the Entrance Roller Release/Stopper HP Sensor (S5)
Connector is physically removed.
4. Replace the Entrance Roller Release/Stopper HP Sensor
(S5).