Troubleshooting > Debug log > Uploading Data by SST > Preconditions:
Troubleshooting > Debug log > Uploading Data by SST > Preconditions:
Uploading Data by SST
The following shows a method to collect a log by connecting a PC with SST (Ver. 4.41 or
later) running to the machine.
■ Preconditions:
The log is stored in the machine by holding down the counter + 1.2.3 or the automatic log
collection function.
A PC with SST running is connected to the machine and the machine is at download mode by
starting it with the 2 and 8 keys.
Note:
Executing a log collection by SST deletes logs in the machine.
1. Start SST (Ver. 4.41 or later) and select iRC2030 from Model List. Press the Start button.
F-6-166
2. Press the Upload Data button.
3. Select the data to be uploaded, then click [Start] button.
When there is no log in the machine, it results in blank option items for "data to upload".
When the file name is longer than the frame, it displays that it is a log in the comment
column just below.
It is displayed as "log" in the figure below.
Note:
The log is not stored when You cancel it before pushing the Start button.
It is deleted from the main body.
F-6-167