Process/Operation > Image Formation System > Controls > Image Stabilization Control
Process/Operation > Image Formation System > Controls > Image Stabilization Control
Related error codes
X indicates the target color (1=Y, 2=M, 3=C, 4=Bk)
E020-0XB0: The TD ration detected by ATR Sensor is higher than the specified value
(high density)
E020-0XB1: The TD ration detected by ATR Sensor is lower than the specified value (low
density)
E020-0X20: The average of density reference value is lower than the specified value at
the time of ATR Sensor initialization.
E020-0X30: The average of density reference value is higher than the specified value
at the time of ATR Sensor initialization.
E020-0X40: Unable to adjust the control voltage at the time of ATR Sensor initialization.
E020-0X41: Unable to adjust the control voltage at the time of ATR Sensor initialization.
E020-0X90: The average of the detected toner density value is low.
E020-0X91: The average of the detected toner density value is high.
E020-0X50: The density for the target is high at patch detection.
E020-0X60: The density for the target is low at patch detection.
E020-1X50: Density is still high even the patch level is set to 0 (failed to be in the target
range between 550 and 640)
E020-1X60: Density is still low even the patch level is set to 7 (failed to be in the target
range between 550 and 640)
● ATVC Control
Transfer failure due to environmental change or deterioration of the Primary Transfer Roller or
the Secondary Transfer Roller can be prevented.
Primary Transfer ATVC
Control timing
1) At power-on
2) When replacing the Drum Unit
3) At recovery from sleep mode
4) At paper interval on a specified print basis or at last rotation
5) At environmental change
Control description
1) Monitor current value of the primary transfer DC bias is detected.
2) Optimal target current value is determined based on temperature/humidity data of the
Environment Sensor.
3) The primary transfer DC bias is determined that is to be applied to the Primary
Transfer Roller.
Secondary Transfer ATVC
Control timing
1) At power-on
2) At every print job
Control description
1) Monitor current value of the secondary transfer DC bias is detected.
2) Optimal target current value is determined based on temperature/humidity data of the
Environment Sensor and paper type.
3) The secondary transfer DC bias is determined that is to be applied to the Secondary
Transfer Roller.
Y
M
C
Bk
DC Controller
PCB (UN9)
Primary Transfer DC Bias
Secondary
Transfer
DC Bias
Environment Sensor (UN45)
F-2-95