7
7
7-7
7-7
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
E
Code
Detail
Code
Location
Item
Description
E003 0006 05
Title
Center Thermistor low temperature detection at printing
Detection In the period from printing to last rotation, Main Thermistor 2
detected a temperature of 80 deg C or lower for more than 1
second.
Remedy Fixing Assembly error, Fixing temperature detection error
1. Check failure between the DC Controller PCB (UN09/ J12) and
the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable,
open circuit, connector disconnection).
-> Replace the part in the case of trapped cable/open circuit
2. Replace the Fixing Assembly
3. Replace the DC Controller PCB (UN09)
NOTE: After performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION > CLEAR >
ERR
E003 0007 05
Title
Edge Thermistor low temperature detection at printing
Detection In the period from printing to last rotation, Sub Thermistor 1
detected a temperature of 80 deg C or lower for more than 1
second.
Remedy Fixing Assembly error, Fixing temperature detection error
1. Check failure between the DC Controller PCB (UN09/ J12) and
the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable,
open circuit, connector disconnection).
-> Replace the part in the case of trapped cable/open circuit
2. Replace the Fixing Assembly
3. Replace the DC Controller PCB (UN09)
NOTE: After performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION > CLEAR >
ERR
E003 0008 05
Title
Edge Thermistor low temperature detection at printing
Detection In the period from printing to last rotation, Sub Thermistor 2
detected a temperature of 80 deg C or lower for more than 1
second.
Remedy Fixing Assembly error, Fixing temperature detection error
1. Check failure between the DC Controller PCB (UN09/ J12) and
the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable,
open circuit, connector disconnection).
-> Replace the part in the case of trapped cable/open circuit
2. Replace the Fixing Assembly
3. Replace the DC Controller PCB (UN09)
NOTE: After performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION > CLEAR >
ERR
E004 0001 05
Title
Fixing Relay PCB welding detection error
Detection Zero cross interruption although relay is not ON.
Remedy Electrical trouble with abnormal fixing safety circuit relay
Replace the AC Driver PCB (UN14)
E
Code
Detail
Code
Location
Item
Description
E004 0005 05
Title
Failure in electrical current detection circuit (abnormal small
current)
Detection Failure in electrical current detection circuit (Less than the
specified range of current value)
Remedy Electrical trouble with abnormal fixing current detection circuit
1. Check failure between the AC Driver PCB (UN14/ J122) and
the DC Controller PCB (UN09/ J10). (trapped cable, open circuit,
connector disconnection) -> Replace the part in the case of
trapped cable/open circuit
2. Replace the AC Driver PCB (UN14)
3. Replace the DC Controller PCB (UN09)
E004 0006 05
Title
Failure in electrical current detection circuit (abnormal large
current)
Detection Failure in electrical current detection circuit (More than the
specified range of current value)
Remedy Electrical trouble with abnormal fixing current detection circuit
1. Check failure between the AC Driver PCB (UN14/ J122) and
the DC Controller PCB (UN09/ J10). (trapped cable, open circuit,
connector disconnection) -> Replace the part in the case of
trapped cable/open circuit
2. Replace the AC Driver PCB (UN14)
3. Replace the DC Controller PCB (UN09)
E009 0000 05
Title
Fixing Film Unit engagement / disengagement error
Detection There is no change in the result of detection by the Fixing
Pressure Release Sensor even after five seconds elapsed after
counterclockwise rotation of the Fixing Motor started.
Remedy Possible cause is overload or rotation failure of the motor due to
an electrical trouble
1. Check if the Fixing Assembly is installed.
2. Remove and reinstall the Fixing Assembly
3. Check the gear
4. Replace the Fixing Assembly
5. Check the harness/connector between the DC Controller PCB
(UN09/ J210) and the Fixing Motor (M17).
6. Check the harness/connector between the DC Controller PCB
(UN09/ J12) and the Fixing Pressure Release Sensor (PS24)
6. Check conduction of FU1153 in the AC Driver PCB (UN14)
=> Replace the AC Driver PCB (UN14) in the case of
disconnection.
7. Replace the Fixing Motor (M17)
8. Replace the DC Controller PCB (UN09)