Service Mode > COPIER > OPTION > DSPLY-SW
Service Mode > COPIER > OPTION > DSPLY-SW
COPIER > OPTION > DSPLY-SW
PUC3-DSP
Init aftr Casstt3 Pckup Rol rplce:usemod
Lv.1 Details
To set whether to display “Paper Feed Rollers (x 2) of Drawer 3” on
Initialization screen after replacing parts in user mode.
When allowing the user to replace the Pickup Rollers of Cassette 3,
set 1.
Use case
When allowing the user to replace the Pickup Rollers of Cassette 3
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Related user mode
Adjustment/Maintenance> Maintenance > Initialize After Replacing
Parts> Paper Feed Rollers (x 2) of Drawer 3
PUC4-DSP
Init aftr Casstt4 Pckup Rol rplce:usemod
Lv.1 Details
To set whether to display “Paper Feed Rollers (x 2) of Drawer 4” on
Initialization screen after replacing parts in user mode.
When allowing the user to replace the Pickup Rollers of Cassette 4,
set 1.
Use case
When allowing the user to replace the Pickup Rollers of Cassette 4
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Related user mode
Adjustment/Maintenance> Maintenance > Initialize After Replacing
Parts> Paper Feed Rollers (x 2) of Drawer 4
UI-CUSTM
ON/OFF of Quick Menu screen display
Lv.2 Details
To set ON/OFF of the Quick Menu screen on the Control Panel.
Use case
When not displaying the Quick Menu screen on the Control Panel
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
1
COPIER > OPTION > DSPLY-SW
CLN-SEL
Set of condensation prev main unit clean
Lv.1 Details
To set the effect of cleaning inside the main unit for condensation
prevention.
When 0 is set, cleaning inside the main unit is not executed.
When 1 to 3 is set, an item for condensation prevention is displayed in
user mode, and the level of effect of cleaning inside the main unit can
be set.
As the value is larger, the effect is increased because ITB cleaning is
executed more frequently, but toner consumption and cleaning time
are increased.
In the case of installation in a low temperature and high humidity
environment (in winter), ask for the user’s opinion and configure the
setting.
Use case
When condensation occurs in a low temperature and high humidity
environment
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 3
0: OFF
1: ON (small effect, low toner consumption)
2: ON (moderate effect, moderate toner consumption)
3: ON (large effect, high toner consumption)
Default value
0