bidirectional_modem
allows you to transmit and receive data after connecting to an asynchronous port.
When you choose
disabled
, you can connect to the port, but communication
cannot occur until the Data Carrier Detect (DCD) modem signal is active. This
parameter is obsolete in Release 10.1.A and in subsequent releases.
broadcast_addr
specifies the IP address for Annex broadcasts (network.255 or network.0).
broadcast_direction
controls the direction in which an Annex sends an administrative broadcast
message. When you choose
network
, the Annex sends a message from the
network side of the connection. If you choose
port
, it sends a message from the
port side. You can use this parameter only when the
mode
parameter is set to
slave
.
bypass
removes the T1 engine from the network. You should enter
enabled
when you
first install an Annex or when the T1 engine is not functioning properly.
Type
Async
Values
enabled or disabled
Default
disabled
Lists
Async Port, Flow Control, Modem
Type
Annex
Values
IP Address
Default
0.0.0.0
Lists
Annex Only, Basic Annex
Type
Async
Values
port or network
Default
port
Lists
Async Port, Basic Async Port, Modem
Type
T1 DS1
Values
enabled or disabled
Default
disabled
Lists
DS1 Line, T1_DS1
Summary of Contents for Manager
Page 10: ...am book amTOC doc x Tue May 6 13 24 47 1997 Annex Manager User Guide Contents x ...
Page 14: ...am book amLOF doc xx Tue May 6 13 24 47 1997 Annex Manager User Guide Figures xx ...
Page 16: ...am book amLOT doc xxii Tue May 6 13 24 47 1997 Annex Manager User Guide Tables xxii ...
Page 22: ...am book pref xxviii Tue May 6 13 24 47 1997 Annex Manager User Guide Preface xxviii ...