Operation using HART communicator
Azbil Corporation
7-40
Model MTG11A/18A, MTG11B/18B, MTG14C
7-3-3 : Other functions
Verifying status of converter
To verify the status and setting of the device, proceed as follow:
1.
From online menu,
Select:
1. Device setup
2. Diag/Service
1. Device Status
Figure 7-90 will then be displayed.
Figure 7-90
2.
There are 3 groups. Each group has
different items to be verified. Figure 7-
91 shows an example of “status group
1”.
Figure 7-91
3.
Table 7-1 shows the items to be verified in each group.
Table 7-1 Items in each group
Group
Item
Description
Group 1
B/O simulation
Burn out status
NVM FAULT
Abnormal non-volatile memory
CPU FAULT
Abnormal CPU
Group 2
IN LOCAL MODE OFF
Changing the setting from display
DO OUTPUT MODE OFF Checking the contact output
PLS OUTPUT MODE OFF Checking the pulse output
AO OUTPUT MODE
Checking the analog output
IN CALIB MODE
Adjusting
NOT CALIBRATED
Non adjusted
EX OUTPUT MODE
Checking the excitation current