Operation using the data setting device
Azbil Corporation
6-16
Model MTG11A/18A, MTG11B/18B, MTG14C
CONFIG functions
The CONFIG functions that are entered by pressing the
key include the
following 17 sub-functions.
UNIT KEY:
Select unit system and setting of specific gravity............6-42
CUT OFF:
Sets and changes low flow ..............................................6-44
DISP:
Changes flow rate display................................................6-46
EX (mA):
Sets detector constant ......................................................6-48
TYPE:
Sets detector type.............................................................6-50
DIAMETER:
Sets detector diameter......................................................6-52
ALARM CONFIG: Sets high alarm and low alarm values .............................6-54
F/S SETUP:
Sets fail-safe direction .....................................................6-56
DIGITAL I/O:
Select pulse output and contact output ............................6-60
Sets contact output status.................................................6-62
DI/DO CHECK:
Output check of contact output .......................................6-64
CORRECT DAC:
Analog output calibration ................................................6-66
GAIN CAL:
Gain calibration ...............................................................6-68
SHIP DATA RECOV:Resets internal data setting to factory setting .................6-70
READ TOTAL:
Reads flow rate counter value..........................................6-71
PULSE OUTPUT:
Checks pulse output value ...............................................6-72
PULSE CONFIGURE:Sets pulse scale and pulse scale unit ..............................6-74
Sets pulse width ...............................................................6-76
Sets dropout .....................................................................6-78
RESET TOTALIZE: Resets flow rate counter................................................... 6-80
m
CAUTION
• Do not operate the following screen from the calibration menu. Operating this
screen will erase all data entered in the electromagnetic flow meter.
B
CONF
SFCM00006003D
CM2-MTG300-2001.book 16 ページ 2015年9月29日 火曜日 午前10時14分
Summary of Contents for MagneW Neo PLUS
Page 16: ...List of Figures Tables CM2 MTG300 2001 book 4...
Page 92: ...MEMO CM2 MTG300 2001 book 38...
Page 106: ...MEMO CM2 MTG300 2001 book 4...
Page 266: ...MEMO CM2 MTG300 2001 book 82...
Page 312: ...MEMO CM2 MTG300 2001 book 46...
Page 336: ...MEMO CM2 MTG300 2001 book 22...
Page 338: ...CM2 MTG300 2001 book 2...