![Azbil MagneW Neo PLUS User Manual Download Page 19](http://html1.mh-extra.com/html/azbil/magnew-neo-plus/magnew-neo-plus_user-manual_3042666019.webp)
Azbil Corporation
Model MTG11A/18A/11B/18B/14C System configuration and structure
Model MTG11A/18A, MTG11B/18B, MTG14C
1-3
System configuration for analog output
System configuration
An example of system configuration is shown. The instantaneous flow rate values
measured by this instrument are output as a 4-20 mA DC analog signal.
In this system configuration, the analog signal from the instrument can be output
directly to a host control system.
• Two wired magnetic flowmeter: Measures flow rate and outputs instantaneous
flow rate value as an analog signal.
• Communicator: Used to communicate with this instrument, read data and change
the instrument data settings.
Figure 1-2-1 System configuration for analog output 1 (Integral type)
Figure 1-2-2 System configuration for analog output 1 (Remote type)
Communicator
SFC / HART
Communicator
4-20 mA
Analog signal
250
Ω
resistance
24 V DC power
Host
control
system
(1-5 V
input)
+
+
+
Grounding *
Two wired magnetic flowmeter
*: The most effective grounding method is direct
connection to earth ground with minimal
impedance.
Communicator
SFC / HART Communicator
4-20 mA
Analog signal
Power supply
24V DC
+
+
+
-
-
-
Host
control
system
(1-5 V
input)
250
Ω
Resistance
Two wired magnetic flowmeter
(Remote type)
Grounding *
*: The most effective grounding method is direct
connection to earth ground with minimal
impedance.
Grounding *
CM2-MTG300-2001.book 3 ページ 2015年9月29日 火曜日 午前10時14分
Summary of Contents for MagneW Neo PLUS
Page 16: ...List of Figures Tables CM2 MTG300 2001 book 4...
Page 92: ...MEMO CM2 MTG300 2001 book 38...
Page 106: ...MEMO CM2 MTG300 2001 book 4...
Page 266: ...MEMO CM2 MTG300 2001 book 82...
Page 312: ...MEMO CM2 MTG300 2001 book 46...
Page 336: ...MEMO CM2 MTG300 2001 book 22...
Page 338: ...CM2 MTG300 2001 book 2...